Asynchronous triggering of JAI M10 BX

 
  Question
 

How can I trigger the Jai M10 BX asynchronously?

  Answer
 

There are two possibilities triggering the camera:

1. The camera is triggered directly:
The camera must be modified to Seal 0 (HD/ Wen Out/ Piexelclock out).
The trigger source must be connected to the 6 pol hirose connector.

2. The framegrabber is triggered:
The camera must be modified to trigger on pin 9 of the 12 pol hirose connector. The trigger source is connected to the framegrabber and the grabber passes the trigger signal to the camera ( Frame Reset).